BARRETT 660 TELEPHONE INTERCONNECT OPERATORS MANUAL Version 1.1 8 Barrett Communications Head Office: European Office: Barre
10 Factory Default will take 30 seconds to complete. Once it is complete the Parameter Editor will default to 'System Clock'. It is now
11 Next you will set 'SCAN Channels' Scroll to 'SCAN Channels ' in the Parameter Editor. The default is 'Empty' Avail
12 'SCAN mode' Options - On, Off Default - Off Available to Options 1, 2 and 3 This parameter is not available for selection until a
14 'Selcall number' Default - 00 (00xx) Available to Options 1, 2 and 3 Entry to this editor is restricted by PIN number security. U
15 ' Answer Delay ' Options - Short, Long Default - Short Available to Options 1, 2 and 3 When the BARRETT 660 is called by a telep
16 'Dialtone Check' Options - On, Off Default - On Available to Options 1, 2 and 3 On some telephone exchanges, particularly older or
17 'Dial-Back Number' Default - Empty Available to Level 3 only When Remote Logging is in use, the internally stored data can be sent
18 'Preset Telephone' Default - All numbers empty Available to Options 1, 2 and 3 The BARRETT 660 has the ability to store 98 preset
19 'User privileges' Options - Suspend Access Restore Access Preset Only Preset and Local (Levels 2 and 3 only) Preset, Local,
1.0 SYSTEM CONCEPT ... 4 2.0 HARDWARE ...
20 The options available perform the following security functions: ' Suspend access ' - This causes the Selcall number(s) to be complete
21 ' No limits ' - This gives the Selcall number(s) access to the system, access to the preset telephone numbers and the ability to
22 twice." ' Access denied ' - This could be sent to either the telephone user or the radio user when they attempt an operat
23 ' RS-232 Speed ' Options - 300 600 1200 2400 4800 9600 19200 Default - 2400 Available to Levels 2 and 3 The 9 Pin 'D' Con
24 When the BARRETT 960 is first switched on, a product identifying message is displayed on the front panel display for 1 second. Following this, a
25 It should be noted that the first character in the table is a 'blank' character and is, of course, selectable. It is recommended that
26 FINAL SETTING UP AND ADJUSTMENTS NOTE: You should be familiar with the Manual Operators menu described in section four of this manual, as wel
27 RV6 on the mother board is not used unless unbalanced audio input is in use. On the voice board there is one adjustment, VR1, this sets
28 5.0 OPERATION After switching on, the BARRETT 660 performs a series of internal checks and displays important system information on the fron
29 Manual Operator's Control Menu Put the BARRETT 660 in the 'Manual' mode by pressing the CANCEL key. If the BARRETT 660 is scannin
6.0 FACILITIES AVAILABLE TO THE TELEPHONE USER ... 32 Selecting a Channel ...
30 Placing ON/OFF Line When placing the BARRETT 960 On Line and Off Line, the current line status is always shown by the front panel LED's. T
31 Using the BARRETT 660 as a Base Station To operate the BARRETT 660 as a Base Station, the Operating Mode should be set to 'Manual' in
32 6.0 FACILITIES AVAILABLE TO THE TELEPHONE USER A telephone user who is using a DTMF telephone handset has the following facilities availabl
33 Sending a Telephone Number This facility is not available to Level 1 Interconnects. In the event that a radio responds to a Selcall, but no vo
34 concepts involved may appear a little uncomfortable to a user who has never used a radio before. The current transceiver state is easily recogni
35 7.0 FACILITIES AVAILABLE TO THE RADIO USER The BARRETT 660 uses a block of 99 selcall numbers. Numbers XX01 to XX98 are for preset Telephone nu
APPENDIX A ERROR MESSAGES ERROR No. ERROR MESSAGE E0 Syntax Error The command received was either mistyped or does not exist. E1
EG No response from GPS. Destination unit timed out during GPS data acquisition, causing it to send back a no response message. EH
APPENDIX B THE PARAMETER EDITOR Overview The BARRETT 660 Telephone Interconnect is a complex and very flexible piece of communications equipment.
1. Operating Mode ' Operating mode ' Options - Automatic, Manual Default - Automatic Available to Options 1, 2 and 3 This parame
4 1.0 SYSTEM CONCEPT The BARRETT 660 Telephone Interconnect is designed to provide telephone interoperability to HF radio users. It is designed
3. Scan Channels ' SCAN Channels ' Default - Empty Available to Options 1, 2 and 3 The BARRETT 660 when fitted to a BARRETT 550
5. Channel Frequencies ' Ch frequencies ' Default - All channels not fitted (000000) Available to Options 1, 2 and 3 The BARRETT 5
6. Selcall Number ' Selcall number ' Default - 00 (00xx) Available to Options 1, 2 and 3 Entry to this editor is restricted by
8. Answer Delay ' Answer Delay ' Options - Short, Long Default - Short Available to Options 1, 2 and 3 When the BARRETT 660 is
11. Remote Logging ' Remote Logging ' Options - On, Off Default - On Available to Level 3 only If Level 3 is fitted to the BARR
13. Dial-Back Time ' Dial-Back Time ' Default - 00:00 (Off) Available to Level 3 only When Remote Logging is in use, the interna
If Level 2 or 3 are fitted to the BARRETT 660, the selecting '99' as the preset number to be edited will result in a list of all current pr
Use the 'UP' and 'DOWN' keys to select the required change. Once the correct option is shown, press the 'END' key to u
complete, 'END' or 'CANCEL' should be pressed when asked for the Start ID. The user is then placed back in the Parameter Editor
18. Play Digital Voice Message ' Play Message ' Options - ' No Dialtone ' 'Call is answered' ' Call con
5 2.0 HARDWARE Front Panel 32 character (16 x 2 lines) backlit, supertwist liquid crystal display. 16 control keys for full operation and editi
20. Start-up Display Message 'Startup message ' Default - ' BARRETT 660 ' ' INTERCONNECT ' (same as the
21. Restore Factory Defaults 'Factory defaults' Available to Options 1, 2 and 3 When an BARRETT 660 has been used for demonstration
APPENDIX C 550 Modification In order for the BARRETT 550 Transceiver to work with the BARRETT 660 a modification must be carried out on the BARRET
6 3.0 OPTION LEVELS There are 3 different option levels of BARRETT 660 Telephone Interconnect available. These are only available factory fitt
7 4.0 PREPARATION FOR OPERATION SYSTEM INTERCONNECTION Ensure that all components to be connected into the system are switched Off. On the BARR
8 SYSTEM START UP Apply power to any external equipment connected to the RS-232 connector. Switch the rocker switch on the BARRETT 522 to the on
9 Parameters available for editing are: 1. Operating mode 2. Scan mode 3. Scan channels 4. VOX operation 5. Channel frequencies 6. Selcall n